Energy Conservation
ENERGY CONSERVATION
- Necessity of energy conservation in hotels:
* It Reduces the Hotel’s Operating Cost: Energy consumption contributes significantly to a hotel’s
operating cost. In general,
energy cost account for 4%-8% of total operating costs. This results in
expensive hotel rates that can lower a hotel’s competitive edge in the
tourism market.
* Energy efficiency can reduce a hotel’s energy cost by
10%-40% depending on the measures taken. This in turn lowers the hotel’s
operating cost, resulting in a higher profit margin and
increased competitive ability of the business.
* It Reduces Climate Change Risks Energy generation is the largest source of
human-induced GHG (Green House Gas) emissions. GHG emissions cause global
climate change, which in turn affects human habitation and livelihood in
many ways.
* It Promotes Green Tourism According
to the World Tourism Organization, ecotourism is the fastest growing
market in the
tourism industry – potentially increasing between 25% and 30% a year.
There is now increasing awareness among tourists about
climate change and concern for the environment.
* There are currently several
certification schemes available for green hotels around the world. These
include regional certification
schemes like Green Seal, Certification for Sustainable Tourism (CST),
etc., as well as globally recognized certification schemes such as Green
Globe, Green Key, Sustainable Tourism Eco-certification Program (STEP),
and others.
Exponential consumption owing
to rising demands has brought fossil fuels- the drivers of industrial
revolution- on the brink of exhaustion.
Grim scenario of depleting these energy resources, human beings
have turned to several non-conventional sources such as sun, water,
wind, tides and biomass to produce electricity.
Still fossil fuels remain the main sources of power generation.
This has also led to an increase in the prices of power as a result of the
huge demand supply gap.
Major resources of energy
The main primary sources of energy used in the hotel industry are
fossil fuels such as coal, petroleum, wood etc. Apart from these,
water or steam energy is also used for producing energy.
Fossil fuels are available
in three forms:-
Solid: Coal, peat, lignite etc.
Liquid: Petroleum products
Gas: Methane, Natural gas etc. and higher gases
The hotel industry mainly uses
natural gas, coal and biogas as fuel sources for heat energy. However,
over the years fossil fuels have been replaced by electrical energy for
the purpose of lighting as well as heating and operating sophisticated
equipment in kitchens. This power is either obtained from the grid
(municipal supply) or captive power plants comprising huge generators
powered by diesel.
Know your fuels (amount of heat
energy produced by) -
* 01 litre of LPG produces 11,850 Kcal
* 01 Kwh of electricity produces 850 Kcal
* 01 litre of light diesel oil (LDO) produces 5,946 Kcal
Electrical energy is also
referred to as ‘artificial’ or ‘manufactured’ fuel in hotel industry.
Electrical energy is produced from other energy sources such as thermal
energy (burning of fossil fuels), hydro power (kinetic energy) etc.
Conventional generation of electrical energy utilizes coal, gas,
oil, or nuclear reactors to heat water, producing high temperature
pressure steam. The steam flows through an electrical turbine generator,
which converts steam power into electric power that is supplied through
the grid for domestic and industrial consumption.
What is energy conservation?
Let us go through the following situation. You are the manager of a 100-room
three-star hotel property located in Agra, which is operating at
cent percent occupancy. Every room is carrying a total connected load of
5.0 Kwh including all types of fixtures, fittings, building system
etc. The power tariff paid to the municipal authorities is @ Rs. 5.00 per
Kwh. How would you compute the annual energy cost (bill) incurred by you
for the rooms?
Solution:-
Total annual cost or amount of
bill= No. of rooms x Connected load x Operating hours a day x Tariff
rate x 365 days of a year
= 100 x 5 x 24 x 5 x 365
= Rs. 2,19,00,000 = 2.19 crore
This is a massive cost. Now you
initiate an energy conservation programme and ask your staff to switch off
all the lights of the guest rooms, when the guests are not in the room.
Assuming that a guest generally spends 2/3 of the time (16 hrs) in the
room and 1/3 of the time outside the room, and the staff follows your
instructions then
The total amount of bill = 100 x 5 x 16 x 5 x 365
= Rs. 1,46, 00, 000
= Rs. 1.46 crore.
The savings made by small efforts is equal to
= Rs. 2,19,00,000 - Rs. 1, 46,00,000
= Rs. 73,00,000 = Rs. 73 lakhs
Thus, we see that savings or
conservation made is an effort to conserve or extend the availability of
our energy resources for a longer period of time for future generations.
At the same time no compromises have been made in maintaining the standard
of services provided by the hotel, plus you are getting monetary benefits
by cutting down the energy expenses and prudently using your energy resources.
The saving made also help soar your profit percent directly without
putting stress on the marketing and
sales team, or the food and beverage service brigade.
Overview of energy cost
There are various forms of energy that are consumed in various
sections of a hotel property; for example, electricity, water, kitchen
gas, district heating, boiler gas, and other fuels. Energy costs of a
hotel vary according to its type, size, location etc. However, the total
energy cost generally ranges from 9 to 13 percent of the total operating
cost of a hotel, or 2 to 3 percent of the total turnover of the hotel
business.
Indian hotels consume
approximately 70% of electricity, 12% water, 4% kitchen gas (LPG), 4%
district heating, 4% boiler gas and 6% other fuels.
Major energy usage department of hotels
Some of the major energy consuming areas/ departments of a hotel
are
the following:-
* Guest rooms
* Food production
* Laundry
* Food and beverage service
* Elevators/ escalators
* Swimming pool
* Hotel Engineering especially in HVAC system which is the
biggest user of energy.
HOW TO CONSERVE ENERGY IN KEY DISCIPLINE AREAS OF A HOTEL
Energy conservation is a team job, and the contribution of every
single staff makes a difference. Therefore, it is important that all
employees be appropriately counseled and apprised of small habits that go
a long way in conserving energy. Some useful tips on power saving for some
energy consuming majors in the industry are enlisted as under:
F
& B department
* Switch on only that equipment which is required.
* Prepare a schedule clearly indicating additional
equipment requirement during peak season.
* Check the capacity of heavy equipment, like ovens, deep fat
fryers, dough kneaders etc. and plan for optimum
capacity utilizations.
* Time required for preheating the oven should be known and
notified to all staff concerned.
* Oven doors not to be opened for longer than necessary for
loading and unloading. Opening doors frequently reduces efficiency
and results in energy loss.
* Switch off ovens, and gas ranges that are not necessary/not in
use.
* Limit the general use of hot water to 1060 F.
* Cook on the largest volume possible.
* Turn down heat as soon as food begins to boil.
* Keep all cooking surfaces clean.
* Bring the frosted meat/vegetables/fruit items to room
temperature before you start cooking.
* Soaking of lentils and rice helps in energy conservation.
* Do not turn on the gas burners until you are ready to cook.
* Timers should be installed on the kitchen equipment.
* Burners should always be turned off before placing the pot or
kettle on them.
* Use flat-bottom pans and pots to maximize heat transfer.
* Regularly check all gas units for uneven or yellow flames.
* Replace the outdated equipment with more energy efficient ones.
* Follow scheduled maintenance of equipment.
* Check proper insulation and earthing of equipment on a
routine basis.
* Proper cleaning and maintenance of equipment reduce
fuel consumption.
* Install chandeliers and other decorative light fixtures in restaurants, coffee
shops, banquets, nightclubs, discotheques etc.
* Banquet is a major section of energy consumption. So, control
the functioning of A.C. according to the time of function.
* Timely defrosting in case of refrigerated equipment helps in
energy conservation.
* Replace incandescent bulbs with LEDs.
Room
Division
* Make use of natural light when designing the rooms. A saving of
half an hour per day results in energy conservation of almost 180 hrs
per room per year.
* Use light finishes for walls and ceilings for better reflection.
* Reduce wattage of lamps with the help of light savers.
* Switch off TV or music in an unused room.
* Keep draperies closed in guest rooms.
* Ensure that leakage in water taps is promptly attended.
* Laundry is a major section of energy consumption in
the housekeeping dept., so develop a regular preventive maintenance
and cleaning programme of the heavy-duty equipment.
* Control neon fixtures, other floodlights and spot fixtures used
for illuminating building exterior on present automatic time switches.
* Place alternate lights in passages, corridors, staircases,
backyards and compounds on separate circuits.
* Practice preventive maintenance.
* Turn off all the lights of all the public areas when not
required.
* Turn off the corridor lights during the day when natural light
is adequate.
* Install master switch controls in all lights of the guest rooms
and which can be synchronized with looking arrangements from
outside the entrance door to turn off and turn on supply of electricity.
* Follow manufacturer’s instructions for maximum output of
an equipment.
Engineering
* Do not deploy reheating for comfort applications; under
perfect conditions reheating units are not desirable.
* Check the quality of water and provide necessary water
treatment solution to prevent scaling and fouling of heat exchangers.
* Switch off HVAC equipment in unoccupied areas paying attention
to the humidity condition.
* Ensure that the heat exchangers, cooling towers, cooling coils
are thoroughly cleaned and maintained periodically.
* Check ventilation and exhaust systems and limit the number of
air changes to the minimum that is acceptable.
* Implement regular cleaning programmes for HVAC system filters.
* All electrical distribution system should be checked and all
the phases are to be balanced.
* Implement an effective preventive maintenance programme for
the boiler house.
* Hot water supply should be adequately insulated to minimize
heat loses.
Food production:
Food preparation in hotel restaurants is a factor in the energy
budget, with cooking using about 6% and refrigeration (not including
guest icemakers) using about 2% of the total energy consumed in the hotel.
In seeking energy savings, consider these opportunities:
Cooking:
* Turn individual pieces of cooking equipment off or down to
an idling temperature during slack production times or when
not needed Operate at the proper temperature, (e.g., fryers at 325˚F
to 350˚F.) Excessive temperature wastes energy and often
results in improperly cooked food. Don’t increase temperature during rush
hours to increase production. Excessive temperature
could destroy the quality of the product and energy consumption will
increase.
* Do not load the units beyond the manufacturer’s
recommended capacity. Overloading results in poor food quality.
* Keep all units clean and properly maintained.
* Establish and implement a regular schedule of
preventive maintenance tasks.
Specific
measures for energy intensive equipment in Food production include –
A.
Fryers. Drain and strain the oil and
check fat levels frequently. This saves oil and preserves food quality.
B. Griddles. Pre-heat only until the
griddle surface has achieved the correct cooking temperature required to
cook the food, and heat only the sections necessary. Clean the griddle
frequently and always re-season. Scrape the cooking surface between
production intervals. Cleaning some types of griddle surfaces requires
special tools - use them. Inspect each griddle section periodically for hot
or cold spots.
C. Broilers. Preheating a broiler for
an extended period of time or at an excessively high temperature wastes
energy and could alter the food quality and taste. Load the broiler to
maximum capacity to gain maximum efficiency. Clean grates frequently - carbonized
grease hinders heat transfer, lowers cooking efficiency, and mars food
quality. Adjust broiler section power. Consider infrared broilers whenever
possible as they may be turned off when not in use and then quickly
reheated when needed.
D. Ovens. Energy efficiency of ovens
depends upon how well they are constructed and used. Insulation levels and
quality are two of the most significant factors in oven design. Some
inexpensive ovens have little-to no insulation in the oven door. In addition,
ovens consume considerable amounts of energy when they are left on, even
when no food is being cooked. If your kitchen production requirement does
not call for a full-sized oven, consider a half-size oven; it will operate
at much better economies.
E. Steamers. Steamer ovens are well
insulated to reduce heat loss to the kitchen. They are quick to preheat
because of the high heat transfer characteristics of steam. Therefore,
they require less energy to stay up to temperature during slow times. Keep
the unit fully loaded when possible as a steamer operates at peak
efficiency and productivity at full capacity.
F. Kitchen Refrigeration: Refrigeration is a vital
tool for almost every food service operator but refrigeration systems have
two strikes against them – they are “On” all the time and they consume
electricity. The hotel has a number of deep freezers and cold storage
rooms. This means that even small amounts of energy wasted by poorly
maintained refrigeration will add up to substantial costs over time. Here
are some practical recommendations to keep refrigeration systems running
efficiently:
* Use strip
curtains or plastic swing doors on cold stores. These “infiltration
barriers” block warm moist air from getting into the
boxes while the door is open. Strip curtains used in busy kitchens can
reduce compressor runtime significantly and that saves lot of energy.
Remember, strip curtains have to cover the entire door opening.
·* Make sure that the doors of the
cold stores are shut all the time. Repair or replace broken auto-closers
on the doors, lubricate
door hinges, and realign sagging doors. Also, don’t allow employees to
prop open walk-in doors.
·* Check all the door
gaskets every fortnightly on all refrigerators and replace any gaskets
that are torn, cracked, worn out, or just plain missing. (Always use the
manufacturer’s specified replacement). A refrigerator door must seal
completely to be effective. Remember, that the proper sealing of doors is
not for keeping the cold air in – it is to keep hot and humid kitchen air
out.
·* Airflow is an important
part of refrigeration. When the coils are clogged and dirty, the
compressor works harder and will fail sooner. Thus it is recommended to
clean the evaporator coil (the cold one inside the refrigerator) and condenser
coil (the hot one
outside the refrigerator or on the roof) at least quarterly. If
the aluminum fins are frozen or bent/damaged then call a qualified
service person for the cleaning. Remember – never use a caustic cleaner on
these coils.
·* Find the time clocks that
control the freezer defrost and set them properly. Time clocks might be
located on top of or underneath the freezers, on the wall, or on the roof.
There is a clock for each freezer. With the help of these clocks, the
number of daily defrost cycles can be reduced from four to three and
sometimes even two. Each cycle should be about 15 minutes long. Also, make
sure
that the evaporator drain line is heated and insulated so that the defrost
condensate has some place to go. Improper defrosting can waste a lot of
electricity and compromise safe freezer temperatures.
·* Use only Compact
fluorescent lamps (CFL) in cold storages. A regular CFL will work fine in
the cold storage but for freezer a low
temperature rated CFL or LED light is required. LED’s would be the ideal
solutions for both applications.
G.
Energy Conservation in Kitchen Ventilation An unbalanced or poorly designed kitchen exhaust system
can spell trouble both for
restaurant’s air quality and for utility bills.
• Catch all that is possible – Cut down on spillage by adding inexpensive
side panels to hoods that are failing to capture, and push each appliance
as far back against the wall as possible to maximize hood overhang and
close the air gap between the appliance and the wall.
• Rebalance the act – If an air balance has not been performed recently,
it’s time to do so. Time, maintenance, broken belts, and
poor commissioning all lead to kitchen exhaust systems that are out of
balance, potentially moving too much or too little air, spilling and
costing money. This also applies to dining room heating, ventilation, and
air conditioning (HVAC) system; outside doors that are hard to open
because of suction or that blow open by themselves are a sure sign that
it’s time to order an air balance.
• Use variable-speed exhaust – Typically, kitchen exhaust hoods have two
settings: “off” and “on”. Naturally, “off” is ideal for when the kitchen
is empty, and “on” may be great for the frenzied lunch and dinner
rush—but neither is quite right for the afternoon lull, the post-dinner
wind down, or any other situation when the kitchen isn’t operating at full
capacity. Variable-speed, demand-based exhaust controls get around this
problem by using sensors to monitor the cooking and varying the exhaust
fan speed to match the ventilation needs. Demand ventilation
controls typically reduce the cost to operate an exhaust system by
anywhere from
30 to 50 % and can be installed on either new installations or retrofitted
to existing hoods.
• Maximize hood size – A 4-foot deep hood is somewhat typical
for restaurant exhaust, but more smoke and heat can be captured if a 5 or
6 foot deep hood is used.
Hotel
Laundry:
One of the large consumers of water and heat in the hotel, laundry is
an outlet that can significantly reduce energy consumption with no effect
on guest comfort or satisfaction. Some of the important points to
achieve desired results are listed below:
• Shift the lights – different switches operating for different corners of
the laundry. This will help in switching off the lights when not
required.
• Clean lamps and lights fixtures every month to maintain the
lighting levels.
• Clean and wash walls, floors and ceiling to allow better reflection of
lights.
• Check and record the water consumption. Compare water consumption daily
to find wastages, if any.
• Consider using cold water detergents. It will greatly reduce
energy consumption.
• Reduce hot water temperature to 48˚C. .
• All steam line values should be checked for leaks. That is, you should
be able to shut off steam to any machine not in use keeping steam
supply main open.
• If possible use final rinse water for 1st wash while washing
uniforms and hotel cloths.
• Reduce time between loads to prevent tumblers from cooling down.
• Air line should be checked for leaks.
• Periodically clean exhaust duct and blower of lint and dust.
• Keep steam pressure at lowest possible level.
• Shut off steam valve whenever machine is not being utilized.
• Keep radiator coils and fins free from dirt all the times.
• Ensure all steam traps in perfect working order.
• Keep an eye on the preventive maintenance schedule of all laundry
equipments by Engineering Department to ensure timely
compliance.
ENERGY
AUDIT
An energy audit is an essential step of energy management. Its objective
is to analyze and evaluate collected data to determine the
energy performance of an entire property and its major consumers.
Simply, energy audit means comparison of the actual performance with
the standard benchmark of a particular equipment to find out the variance
in terms of the actual and desirable performance.
Some useful tips while conducting the energy audit are as
follows:-
·* Carry out a departmental
energy audit to get a fair idea of major energy consumers.
·* Compare the result to determine
potential savings from a section or department.
·* Energy audit should be
done on a regular basis.
·* Convert energy units to
Kwh.
·* Establish a monitoring
and targeting system.
·* Install sub meters for
each utility.
·* Calculate on monthly basis
energy consumption per kg for laundry.
·* Compare the result with
benchmarks and calculate the difference in percentage and money to see how
much could be saved.
STEPS
OF ENERGY MANAGEMENT
Step
1 – Management and planning The first step is to identify a team to oversee energy
management in a hotel. The team should comprise management-level staff
(owners, managers), technical staff, financial staff, and housekeeping.
Large hotels usually have an engineering department and full-time
technicians for regular maintenance of hotel facilities.
Step 2 – Energy Assessment Knowing the hotel’s
energy consumption is critical to developing an energy management plan. A
detailed energy audit is the best way to identify where energy is being
consumed, and how to improve energy efficiency. A detail audit needs to be
carried out to measure power consumption for a certain period of time. It
requires an allocation of resources and time to conduct a useful and
detailed energy audit.
Step 3 – Benchmarking is an analysis based on
the performance or energy consumption of a given hotel, followed by
subsequent comparison to the performance of other hotels in similar
environments. Levels of energy consumption tend to vary by hotel
classification and climate conditions. As a result, hotels are generally
classified by size, (number of rooms) and star rating (facilities and
comfort levels).
Step 4 – Measures to improve energy
efficiency can be implemented by changing behavior and simple maintenance
activities that require little or no investment. These measures can
effectively reduce energy consumption, often to a significant degree.
Hotel owners may also choose to replace old appliances with more efficient
ones. This requires capital investment, but can drastically reduce a hotel’s
energy cost within a potential payback period of 2-5 years.
Step 5 – Evaluate After implementing energy
efficiency measures, it is important that energy managers monitor the
level of energy consumption by keeping records of energy and water consumption,
and subsequently evaluating the results of implemented measures. This
information is important for the hotel management for the purposes of
calculating operating cost and profit margins, and for maintaining the
energy consumption at a low level.
Energy
Conservation Program
Once an energy audit is complete, the next logical step is to draw out
and execute the exercise to accomplish energy consumption in sectors of
the hotel where there is scope. This exercise constitutes the
energy conservation programme. It must, however, be borne in mind that
energy conservation is not a one man or one department programme. It
requires involvement and commitment of every employee of the hotel from
General Manager to the entry-level staff of any section.
Generally, an energy committee is constituted with the head of
the committee being appointed from the department concerned.
The committee is tasked to plan, implement, and monitor the
energy conservation programme. The details of the philosophy of the
programme are left to the committee. The committee must be made aware that
the energy conservation programme is a three-phase programme. The
flow chart mentioned in the next page (page 13) will clear the idea.
The first phase includes the things that can be done immediately
with minimum inconvenience to the guests as well as to the organization.
The point to remember here is that there is no budget for an
energy conservation programme, so the payoff of this phase is usually
fairly large for the efforts put in.
The second phase involves readjustment of the operational
practices. The savings made in these two phases should be fed back into
the operations so that the third phase can be implemented.
The third phase involves changes in the physical property, which
may require the owners’ investment plus the savings made in the first
and second phases. For instance, installation of equipment would
be instrumental in conservation.
Flow
Chart for Developing an Energy Conservation Program
Phase One
Step 1 Collect data on
consumption of energy and convert it into the amount.
Step 2 Compare the data with the benchmark by performing an
energy audit.
Step 3 Analyze the findings and identify a department where
differences are highest.
Step 4 Call a meeting and invite the head of the department and
his/her team for discussion on the results.
Step 5 Seek their suggestions and ask about the problems faced by
them regarding the poor performance in the energy audit.
Step 6 Appoint an energy conservation committee headed by
the departmental head and give them a target to reduce energy
consumption within a set time frame.
Phase
Two
Step 7 Review the results of phase
one. If the results are positive after the target time, commend the
efforts of the task force and seek their suggestions to invest the savings
in the second phase. Allow them to make certain changes in the existing
standard operating practices / minimum investment in replacing the light
equipment / accessories. Give them a target to reduce energy consumption
within a set target time in the second phase.
If the results are not encouraging, then repeat the first phase
till the desired results are obtained.
Phase Three
Step 8 Review the results of phase two
after the target time. If the results are positive, then praise the
efforts of the task force and solicit their advice. Invite the senior
management / owners for a discussion on the success story of the task
force. Ask for the owner’s investment in making changes in the
infrastructures, building systems, and inducting the latest technology,
etc. to further improve energy conservation. If the results are not
encouraging, then the second phase is repeated till the time the desired
results are obtained.
Very informative
ReplyDeleteThank you for the notes sir
Well explained... Thank you for the notes sir
ReplyDeleteInformative notes thank you sir
ReplyDeleteKnowledgeable stuff Sir. Thank you Sir for sharing the notes.
ReplyDeleteVery well explained..!!
ReplyDeleteThankyou sir for this valuable information 😊
ReplyDeleteThank you sir for the lovely notes
ReplyDeleteThank you sir.
ReplyDeleteEnlightening Content
ReplyDeleteThank you Sir
Very informative
ReplyDeleteThnq sir
Thank you for informative notes sir
ReplyDeleteNicely explained sir
ReplyDeleteThank you sir
ReplyDeleteThnks sir for providing information notes
ReplyDeleteSachin kumar.